- Repair or address any sunken or heaved concrete that has a difference in height and any cracks that are 1 inch or more
- Repair any erosion caused by gutter downspouts or storm water that appears on the property
- Remove and dispose of any junk and debris on the exterior areas of the building including garbage, brush, interior furniture, etc
- Ensure the lawn and landscaping are free of noxious weeds such as thistles
- Make sure vehicles are all in a functional state and have current license plate tabs
- Check that all siding is in good condition and free of holes and cracks
- Make sure any penetrations such as air conditioning lines, vents & gas lines are properly sealed to prevent the entrance of moisture and pests
- Check dryer vents for cleanliness & the backdraft flaps are properly functioning and no screens or grids are attached to the dryer vent
- Make sure all soffit and fascia are in place and not missing
- Check all painted surfaces including window & door trim, siding, soffit & fascia are not peeling or rotted
Rental Inspections
New rental properties are inspected when you apply for a Rental Housing Certificate. This is an automatic 2-year inspection interval result. After that initial two years, routine inspections are also required.
The inspection frequency depends on a property’s score, based on the violations and will result in one of the following:
- Every 4 years
- Every 3 years
- Every 2 years
- Every year
Routine inspections can be scheduled any time after your renewal letter is sent. To stay in compliance, we highly recommend you complete the routine inspection before the rental certificate expires.
Request an inspection by submitting an Inspection Request form or calling (507)328-2600 during office hours.
Note: only the property owner or manager may escort the Housing Inspector through the rental property.
Pre-Inspection Rundown
Pre-Inspection Rundown By Room
- Flooring throughout the home is in good condition, with no damage, holes, peeling, separation, fraying, etc.
- No holes in walls, ceilings or doors
- No peeling, flaking or blistered paint or texture
- No fogged window glass
- Screens in place on all windows & doors from June 1 to October 15 without damage. Grade-level windows must have screens installed year-round.
- Egress paths must be free of obstructions; bedroom windows & doors, entry & sliding glass doors, etc.
- All electrical plates for switches, outlets, etc., are in place
- All GFCI outlets throughout the home test and reset
- Light fixtures are properly installed with globes/ lenses and functioning
- No missing light bulbs
- No major appliances on extension cords or power strips; fridges, freezers, ACs, sump pumps, water softeners, laundry equipment, etc.
- No cords ran in a way that they could pose a tripping hazard
- Every level of a dwelling must have a smoke detector (basement, main, second & attics)
- Fire extinguishers are required in every building with three or more units, within 75 feet of every entrance door or located in every unit
- Fire extinguishers are required to be serviced and tagged yearly or replaced yearly
- Ensure all smoke & CO detectors are not expired; 10 years old or older from the manufacture date
- All buildings with RPZs, fire sprinkler, fire alarm panels & lawn irrigation backflow devices are to be serviced & tagged yearly
- No flexible drain piping on any plumbing fixtures
- Bathroom fixtures are secure & not loose
- Tub & vanity fixtures not dripping when in off position
- Pop-ups or screens present in the tub & vanity drains
- Ventilation fans clean & operable
- Toilet not running, flushes properly with a secure & properly fitting toilet seat
- Toilet secured to floor
- No biological growth on any surfaces: walls, ceilings, caulking, grout, etc.
- Vanity cabinet doors & drawers in place and working properly
- No leaks present in the bathroom
- Hand-held shower heads have appropriate backflow protection if the shower head reaches below the water line
- The tub diverter is fully operational, with no leaking when diverted
- Egress windows are not blocked, can fully open and stay open (unless fully sprinkled)
- Appropriate smoke detector present & operational
- CO detector and smoke detector located within 10 feet outside of every bedroom and CO in every bedroom with a gas burning appliance in the bedroom (Note: New State Statute Section 299F.51 now employs different situational requirements)
- Ensure the laser sensor for the auto reverse on garage door openers is working
- If the garage is attached to the dwelling, make sure there are no holes or unsealed penetrations in the firewall between the garage and the dwelling
- If your garage has an attic access panel, make sure it is fire-rated and in place (do not seal the attic access)
- Check all outdoor light fixtures for bird nests built on or in the fixture and remove if present
- Dryer vents should be clean, with backdraft flaps able to close and no installed screens or grids
- Check the condition of siding: missing, rotting, holes, peeling paint, etc. Check for missing soffit & fascia
- Check around AC lines, gas lines and other penetrations to make sure they are still properly sealed
- Check all paved surfaces for heaving, settling and/or separations of 1 inch or greater
- Remove any junk, trash or debris from the exterior of the property
- Trim back or remove any vegetation that is growing against or in any structures
- Ensure garbage disposal works, has a strain relief/romex clamp on the cord, doesn’t leak & has a proper splash guard installed
- Check the kitchen faucet aerator and drain for drips & leaks, and that it is secure
- Ensure all burners on the stove work
- Remove any foil on the stove top, in the oven and on burners
- Make sure the range hood/microwave surface lights and exhaust fan work & covers are present
- Check that grease filters are in place on the range hood/microwave & that it’s clean
- Check all kitchen appliances to make sure there are no broken parts & replace/repair if there are
- Furnace filter installed, correct size, clean and with cover in place
- The temperature, pressure valve and drain valve on the water heater are not leaking
- Water heater not leaking
- The breaker panel has no open breaker slots
- 36-inch clearance of stored items around the fuel-burning furnace and water heater
- The breaker panel needs clearance of 30 inches in width and 36 inches in front of the panel. Sump pump cover in place
- Dryer vent attached with no duct tape at the seams and no vinyl flex duct
New Use Inspection (in addition to those above)
- Measure headroom on all stairwells to ensure it is 6 feet 4 inches along the entire plane of the stairs
- Every habitable room must be at least 7 feet in length and width, with a minimum floor area of 70 square feet (excluding kitchens, which must be at least 3 feet between working surfaces and appliances)
- Every habitable room must have a ceiling height of 6 feet 4 inches
- Measure each egress window in sleeping rooms, ensuring the window is fully open and stays fully open, to ensure the minimum width, height, total open area and sill height requirements are met
- Check egress window wells for debris, size and depth, ladder if required and easily removable cover if a cover is present
- Tempered glass or film installed, if older windows, in all required hazard areas, 18” from the floor
Bring these items to your inspection:
- 9-volt and AA batteries
- Extra sink strainer
- Disposal wrench
- Furnace filter
- Extra lightbulbs